- Found at :
- www.aliexpress.com
MQ2
High sensitve multiple gas sensor especially for LPG, Propane and Hydrogen.
If you are using just MQ2(not module), Then prepare load resistance around 2k ohm.
This sensor need pre-heating. To get stable output, wait for heat-up, minimum 2 minutes.
This library get analog voltage from a sensor. Output voltage will increase regarding gas level. When you need actual level (ppm), you should do calibrate the sensor and prepare a formula.
wired(obniz, { vcc, gnd, do, ao});
name | type | required | default | description |
---|---|---|---|---|
vcc | number(obniz io) |
no | VCC or H on MQ2. | |
gnd | number(obniz io) |
no | GND or H on MQ2. | |
do | number(obniz io) |
no | digital out | |
ao | number(obniz io) |
no | analog out |
// Javascript Example
var mq2 = obniz.wired("MQ2", {vcc:3, gnd:2, do:1, ao:0});
await mq2.heatWait();
mq2.onchangeanalog = function(voltage) {
console.log(voltage);
}
startHeating()
It start heating.
// Javascript Example
var mq2 = obniz.wired("MQ2", {vcc:3, gnd:2, do:1, ao:0});
mq2.startHeating();
[await] heatWait(sec: number)
It start heating and wait for a while.
You can update wait time.
name | type | required | default | description |
---|---|---|---|---|
sec | number |
no | 120 | seconds for wait |
// Javascript Example
var mq2 = obniz.wired("MQ2", {vcc:3, gnd:2, do:1, ao:0});
await mq2.heatWait();
mq2.onchangeanalog = function(voltage) {
console.log(voltage);
}
onchangeanalog = function(voltage: number)
Specified function will be called every voltage change.
// Javascript Example
var mq2 = obniz.wired("MQ2", {vcc:3, gnd:2, do:1, ao:0});
await mq2.heatWait();
mq2.onchangeanalog = function(voltage) {
console.log(voltage);
}
onexceedvoltage = function(voltage: number)
Specified function will be called only when a voltage exceed voltageLimit variable.
// Javascript Example
var mq2 = obniz.wired("MQ2", {vcc:3, gnd:2, do:1, ao:0});
await mq2.heatWait();
mq2.voltageLimit = 1.0
mq2.onexceedvoltage = function(voltage) {
console.log(voltage);
}
voltageLimit = number
It define the level of onexceedvoltage call.
// Javascript Example
var mq2 = obniz.wired("MQ2", {vcc:3, gnd:2, do:1, ao:0});
await mq2.heatWait();
mq2.voltageLimit = 1.0
mq2.onexceedvoltage = function(voltage) {
console.log(voltage);
}
onchangedigital = function(voltage: number)
This function only be called when do was specified at wired function.
do output high/low regarding output. It compared in a module.
This function will be called every change of do.
// Javascript Example
var mq2 = obniz.wired("MQ2", {vcc:3, gnd:2, do:1, ao:0});
await mq2.heatWait();
mq2.onchangedigital = function(value) {
console.log(value);
}
Supported from: obniz.js 3.5.0