Logtta_AD
CO2 concentration sensor by UNI-ELECTRONICS
Official product introduction page is here
Available modes
- Beacon mode
- Connectable mode
Beacon data (getData())
- battery: Battery level (%) or USB power supply (254)
- ampere: Ampere (mA) (4~20)
- volt: Voltage (mV) (1000~5000)
- count: Contact input counter
- interval: Transmission interval (sec)
Connected data (getDataWait())
- ampere: Ampere (mA) (4~20)
- volt: Voltage (mV) (1000~5000)
- count: Contact input counter
Use case (Beacon mode)
// Javascript
const Logtta_AD = Obniz.getPartsClass('Logtta_AD');
await obniz.ble.initWait();
obniz.ble.scan.onfind = async (peripheral) => {
// Get operation mode, it becomes null when not Logtta_AD
const mode = Logtta_AD.getDeviceMode(peripheral);
if (mode === 'Beacon') {
// Generate an instance
const device = new Logtta_AD(peripheral, mode);
// Get data and output to the console
console.log(device.getData());
}
};
await obniz.ble.scan.startWait(null, { duplicate: true, duration: null });
Use case (Connectable mode)
Connect then get data & battery remaining once
Use batteryService.getBatteryLevelWait()
to get battery levels.
When the value is 254, the USB power supply is driven, otherwise the remaining amount is returned in percentages.
// Javascript
const Logtta_AD = Obniz.getPartsClass('Logtta_AD');
await obniz.ble.initWait();
obniz.ble.scan.onfind = async (peripheral) => {
// Get operation mode, it becomes null when not Logtta_AD
const mode = Logtta_AD.getDeviceMode(peripheral);
if (mode === 'Connectable') {
// Generate an instance
const device = new Logtta_AD(peripheral, mode);
console.log(`Connecting to Logtta_AD[${device.address}]`);
// Connect to the device
await device.connectWait();
console.log(`Connected to Logtta_AD[${device.address}]`);
// Get data from the device
const data = await device.getDataWait();
console.log(`Logtta_AD[${device.address}]: ${data.ampere}mA`);
console.log(`Logtta_AD[${device.address}]: ${data.volt}mV`);
console.log(`Logtta_AD[${device.address}]: ${data.count} time(s)`);
if (device.batteryService) {
// Get battery level from the device
const batteryLevel = await device.batteryService.getBatteryLevelWait();
// Output 'USB power supply' at 254
if (batteryLevel === 254)
console.log(`Logtta_AD[${device.address}]: USB power supply`);
// Output battery remaining amount when other than 254
else
console.log(`Logtta_AD[${device.address}]: BatteryLevel ${batteryLevel}%`);
}
// Disconnect from the device
await device.disconnectWait();
console.log(`Disconnected from Logtta_AD[${device.address}]`);
}
};
await obniz.ble.scan.startWait();
Connect then regularly get data
Use startNotifyWait()
to wait for data from the device always.
// Javascript
const Logtta_AD = Obniz.getPartsClass('Logtta_AD');
await obniz.ble.initWait();
obniz.ble.scan.onfind = async (peripheral) => {
// Get operation mode, it becomes null when not Logtta_AD
const mode = Logtta_AD.getDeviceMode(peripheral);
if (mode === 'Connectable') {
// Generate an instance
const device = new Logtta_AD(peripheral, mode);
console.log(`Connecting to Logtta_AD[${device.address}]`);
// Connect to the device
await device.connectWait();
console.log(`Connected to Logtta_AD[${device.address}]`);
// Start waiting for data from the device
device.startNotifyWait((data) => {
console.log(`Logtta_AD[${device.address}]: ${data.ampere}mA`);
console.log(`Logtta_AD[${device.address}]: ${data.volt}mV`);
console.log(`Logtta_AD[${device.address}]: ${data.count} time(s)`);
});
}
};
await obniz.ble.scan.startWait();
Connect then activate beacon mode
Use setBeaconModeWait()
to control the valid invalidity of the mode that periodically disseminates beacons.
Disconnecting after setting it is effective.
Before need use authPinCodeWait()
to authenticate with the device. (Default authentication code: 0000)
To disable beacon mode, it is necessary to press and hold the button on the device for more than 2 seconds.
// Javascript
const Logtta_AD = Obniz.getPartsClass('Logtta_AD');
await obniz.ble.initWait();
obniz.ble.scan.onfind = async (peripheral) => {
// Get operation mode, it becomes null when not Logtta_AD
const mode = Logtta_AD.getDeviceMode(peripheral);
if (mode === 'Connectable') {
// Generate an instance
const device = new Logtta_AD(peripheral, mode);
console.log(`Connecting to Logtta_AD[${device.address}]`);
// Connect to the device
await device.connectWait();
console.log(`Connected to Logtta_AD[${device.address}]`);
// Send authentication code
await device.authPinCodeWait(0000);
console.log(`Logtta_AD[${device.address}]: Sent auth pin code`);
// Enable beacon mode
await device.setBeaconModeWait(true);
console.log(`Logtta_AD[${device.address}]: Enabled beacon mode`);
// Disconnect from the device
await device.disconnectWait();
console.log(`Disconnected from Logtta_AD[${device.address}]`);
}
};
await obniz.ble.scan.startWait();
Supported from: obniz.js 3.5.0