Account owners can inspect physical devices and update firmware in [obniz device management](https://now.obniz.com/admin/devices). This screen covers obniz devices linked to Machines in Now. Use the [Machine list](device-list) to find sensor data.

Updates require the Account's obniz Cloud connection to be configured. If no firmware versions can be loaded, ask your deployment contact to check that connection.

## Select devices

1. Open `/admin/devices` and search by obniz ID or Machine name.
2. Check the hardware, current firmware, and update status.
3. Open the bulk update dialog and select the hardware type and target firmware.
4. Select up to 100 devices of the same hardware type.
5. Confirm the IDs, names, current and target versions, and device count before starting.

Supported hardware identifiers are `iekilo1`, `iemicro1`, `blewifi_gw2`, `blelte_gw2`, `ak030`, and `encored`. Devices with unknown or mismatched hardware, the target firmware already installed, or an update in progress cannot be selected. Changing the hardware type clears the selection.

## Check each device after acceptance

Keep devices powered and connected during updates. The list distinguishes queued, updating, finished, failed, and offline states. It refreshes status every 15 seconds while there are update targets. After completion, reload device information and verify the installed firmware.

An accepted request means the update was registered; it does not establish successful installation. Check previous results in [update history](https://now.obniz.com/admin/devices/history). A failure during a batch also marks the remaining devices as failed because processing was stopped. Read the error reason to distinguish devices that were attempted from devices that were skipped after the failure.

| Situation | Check next |
| --- | --- |
| Device missing from the list | Selected Account, search filters, and Machine linkage |
| Offline device was not updated | Restore power/connectivity, then check history and current status |
| No progress after acceptance | Check history and give the deployment contact the obniz ID and acceptance time |
| Connection failed and the result is unknown | Reload the existing update before sending the same request again |

## Update through the API

`POST /api/1/firmware/update` accepts the following JSON. User sessions require an owner; API keys require Write permission for `firmware_updates`. See [API authentication](../integration/api-authentication) for the authentication method.

```json
{
  "deviceIds": ["1234-5678"],
  "firmwareVersion": "<selected target version>",
  "skipOffline": true
}
```

`skipOffline` defaults to `true`, skipping offline devices and continuing. With `false`, an offline failure stops subsequent updates. Treat HTTP 202 and the returned `jobId`, `queued`, and `total` as acceptance information, not successful-update counts. Use `GET /api/1/firmware/latest-update` for status and `GET /api/1/firmware/history` for history.